Thermogram

Thermogram

BRAKING RESISTOR THERMOGRAM FOR BRIDGE CRANE
TEST IN CHARGE


Thermogram 1
Resistors of the vertical movement after two consecutive movements, of fast up and down, in strict conditions of working, with the temperature below the accepted value. Charge of 66.5 tons. Temperature at the resistive element.


       


Thermogram 2
Resistors of the vertical movement. Temperature at the cables after two consecutive movements of fast up and down. Charge of 66.5 tons.


Observations:
The thermograms in this report were registered during the charge capacity test of the bridge crane.
The temperature values showed at the thermograms represent the maximum found and are almost below of the acceptable value.


       

       

       

       